A Portable Heat-Exchange-Based System for Assessing Digital Vascular Response to Cold
Main Article Content
Keywords
Finger blood flow, Strain-gauge plethysmography, Heat exchange, Local cooling, Peripheral perfusion, Hand-arm vibration syndrome, Vibration-induced white finger, Raynaud’s phenomenon, Occupational health surveillance
Abstract
Background: Digital vascular assessment is relevant in occupational medicine, but current measurement methods may be complex and poorly portable. Objective: To validate a portable heat-exchange-based system for assessing cold-induced digital vascular response, using strain-gauge plethysmography as the reference method. Methods: Twenty healthy volunteers, 10 males and 10 females, underwent five subsequent sessions. Finger blood flow (FBF) was assessed by strain-gauge plethysmography, while simultaneously, fingertip thermal power (TP) was recorded with a portable thermoflowmeter. FBF was measured at baseline, while both FBF and TP were measured during application of 1-N contact force alone and during 1-N force combined with local cooling at 10 °C. The relationship between TP and FBF, after adjustment for covariates (age, sex, body mass index (BMI), and room temperature), was evaluated in the cooled condition using a linear mixed model including fixed and random effects. Results: Local cooling induced a significant vascular response, with FBF decreasing from 1.23 to 0.98 ml/100 ml/s (p<0.0001). In the cooled-condition model, TP was significantly associated with FBF, with each 1 ml/100ml/s increase in FBF corresponding to a 39.6 mW increase in TP (p<0.0001). Under cooling, TP showed lower within-subject variability than FBF (wsCV ≈0.19 vs ≈0.64). BMI was positively associated with TP (4.40 mW per kg/m², p=0.007), whereas age and sex were not significant predictors. Conclusions: These findings support the interpretation of TP as a perfusion-related thermal descriptor with potential applicability in occupational health surveillance. Further validation in subjects with digital vascular disorders is needed.
References
2. Taylor W, Wasserman D, Behrens V, Reynolds D, Samueloff S. Effect of the air hammer on the hands of stonecutters. The limestone quarries of Bedford, Indiana, revisited. Br J Ind Med. 1984;41(3):289-295. Doi: 10.1136/oem.41.3.289
3. Bovenzi M. Vibration-induced white finger and cold response of digital arterial vessels in occupational groups with various patterns of exposure to hand-transmitted vibration. Scand J Work Environ Health. 1998;24(2):138-144. Doi: 10.5271/sjweh.291
4. Tekavec E, Nilsson T, Dahlin LB, et al. Serum levels of biomarkers related to severity staging of Raynaud's phenomenon, neurosensory manifestations, and vibration exposure in patients with hand-arm vibration injury. Sci Rep. 2024;14(1):18128. Doi: 10.1038/s41598-024-68846-1
5. Bovenzi M. A longitudinal study of vibration white finger, cold response of digital arteries, and measures of daily vibration exposure. Int Arch Occup Environ Health. 2010;83(3):259-272. Doi: 10.1007/s00420-009-0461-2.
6. Bovenzi M, Tarabini M. Relation of digital arterial dysfunction to alternative frequency weightings of hand-transmitted vibration. Ind Health. 2024;62(1):32-38. Doi: 10.2486/indhealth.2023-0023
7. Mahbub M, Harada N. Review of different quantification methods for the diagnosis of digital vascular ab-normalities in hand-arm vibration syndrome. J Occup Health. 2011;53(4):241-249. Doi: 10.1539/joh.10-0030-ra.
8. Lindsell CJ, Griffin MJ. Normative data for vascular and neurological tests of the hand-arm vibration syn-drome. Int Arch Occup Environ Health. 2002;75(1-2):43-54. Doi: 10.1007/s004200100277
9. Matikainen E, Leinonen H, Juntunen J, Seppäläinen AM. The effect of exposure to high and low frequency hand-arm vibration on finger systolic pressure. Eur J Appl Physiol Occup Physiol. 1987;56(4):440-443. Doi: 10.1007/BF00417772.
10. Ye Y, Mauro M, Bovenzi M, Griffin MJ. Reduction in finger blood flow induced by hand-transmitted vibra-tion: effect of hand elevation. Int Arch Occup Environ Health. 2015;88(7):981-992. Doi: 10.1007/s00420-015-1027-0
11. Ye Y, Mauro M, Bovenzi M, Griffin MJ. Association between vasoconstriction during and following exposure to hand-transmitted vibration. Int Arch Occup Environ Health. 2014;87(1):41-49. Doi: 10.1007/s00420-012-0836-7
12. Jay O, Havenith G. Differences in finger skin contact cooling response between an arterial occlusion and a vasodilated condition. J Appl Physiol (1985). 2006;100(5):1596-1601. Doi: 10.1152/japplphysiol.00760.2005.
13. Greenfield AD, Whitney RJ, Mowbray JF. Methods for the investigation of peripheral blood flow. Br Med Bull. 1963;19:101-109. Doi: 10.1093/oxfordjournals.bmb.a070026.
14. Chen F, Nilsson H, Holmér I. Finger cooling by contact with cold aluminium surfaces--effects of pressure, mass and whole body thermal balance. Eur J Appl Physiol Occup Physiol. 1994;69(1):55-60. Doi: 10.1007/BF00867928.
15. Bland JM, Altman DG. Measurement error. BMJ. 1996;312(7047):1654. Doi: 10.1136/bmj.312.7047.1654
16. Fruhstorfer H, Abel U, Garthe CD, Knüttel A. Thickness of the stratum corneum of the volar fingertips. Clin Anat. 2000;13(6):429-433. Doi: 10.1002/1098-2353(2000)13:6<429::AID-CA6>3.0.CO;2-5
17. Jay O, Havenith G. Finger skin cooling on contact with cold materials: an investigation of male and female responses during short-term exposures with a view on hand and finger size. Eur J Appl Physiol. 2004;93(1-2):1-8. Doi: 10.1007/s00421-004-1146-x